| Properties of medium | Single phase liquid with <5% solid content, <2% gas content and max. 100 cSt |
|---|---|
| Option | High viscosity version up to 1000 cSt |
| Ambient temperature | -40…+65°C; -40…+149°F |
| Process temperature | Compact version: -45…+140°C; -49…+284°F Remote version: -45…+180°C; -49…+356°F Extended temperature version: -45…+250°C; -49…+482°F (only remote) Cryogenic version: -200...+180°C; -328…+356°F (only remote) High viscosity version: -45…+180°C; -49…+356°F |
| Process connections | EN1092-1: PN6…100; ASME B16.5: 150…900 lbs |
| Measuring range | v = 0.3…20 m/s; 1…66 ft/s (bi-directional) |
| Accuracy (under reference conditions) | ±0.3% of measured value ±2 mm/s |
| Repeatability | 0.2% |
| Inlet run | Minimum 5DN |
| Outlet run | Minimum 3DN |
| Mounting orientation | Horizontal and/or vertical |